Permit-ready NRCC energy compliance for California warehouses — high-bay lighting, daylighting controls, and any conditioned space scoped from your plans.

Request Commercial Quote → Contact Us

Warehouses are large-footprint buildings where lighting and, in some cases, daylighting dominate the energy scope, while HVAC may be limited to offices or conditioned areas. New warehouse construction and warehouse tenant improvements in California require Title 24 (Part 6) documentation for permit.

High-bay lighting and daylighting

Warehouse lighting uses high-bay fixtures, and the Energy Code requires appropriate controls — occupancy sensing and, in large open areas, daylighting controls tied to skylights. Interior lighting is documented on NRCC-LTI, and site and exterior lighting on NRCC-LTO. Because warehouses have large floor areas, lighting power and controls are usually the central part of the report.

Conditioned vs unconditioned space and envelope

Not all warehouse area is conditioned. The report must distinguish conditioned space (typically offices, sometimes climate-sensitive storage) from unconditioned storage, since HVAC (NRCC-MCH) and envelope (NRCC-ENV) requirements apply to conditioned areas. Refrigerated or cold-storage areas add process-load scope (NRCC-PRC). We prepare the certificates that match how the building is actually conditioned.

Skylights, roofs, and site lighting

Warehouse envelope scope centers on the roof and any skylights, which affect both insulation for conditioned areas and whether daylighting controls are triggered for the lit floor below. Cool-roof and insulation details for conditioned space are documented on the envelope certificate, while yard, canopy, and site lighting fall under outdoor lighting (NRCC-LTO). Providing roof and skylight details alongside the lighting plan lets us confirm whether daylighting controls apply and prepare the envelope and outdoor lighting certificates accurately, so the report matches how the building is actually built and lit.

What we need to quote and prepare your report

Send the full plan set so we scope lighting, daylighting, and any conditioned areas:

Example project

Illustrative example — not a specific customer: A 40,000-square-foot distribution warehouse has high-bay LED lighting with occupancy and daylighting controls, skylights over the main floor, and a small conditioned office. The project needs NRCC-LTI for lighting and controls and NRCC-MCH/NRCC-ENV for the conditioned office; lighting controls are then verified through acceptance testing.

Commercial Title 24 pricing

Commercial projects are quoted individually — priced by building type, conditioned floor area, compliance path, and the systems in scope, not a flat rate. Upload your plans for a firm quote, with standard, rush, and same-day options.

Request a commercial quote →

← Back to Commercial Title 24 · All services · Request a quote

Questions & Answers

Does an unconditioned warehouse still need Title 24?
Lighting requirements generally apply even to unconditioned warehouse space, so an indoor lighting certificate is usually required. HVAC and envelope requirements apply to conditioned areas.
Are daylighting controls required?
Large open lit areas with skylights typically require daylighting controls. We confirm applicability from your lighting and skylight plans.
How is conditioned space handled?
We separate conditioned areas (offices, climate-sensitive storage) from unconditioned storage, because HVAC and envelope requirements apply to the conditioned portion.
What about cold storage or refrigeration?
Refrigerated and cold-storage areas add process-load scope documented on NRCC-PRC. Note these areas so we scope them correctly.
What do you need to quote a warehouse?
Plans showing conditioned vs unconditioned areas, the lighting plan and fixture schedule, and mechanical plans for any conditioned space.
How is a warehouse quoted?
By floor area, lighting scope, and any conditioned or refrigerated areas — not a flat rate. Upload plans for a firm quote.

Related Title 24 Topics

Browse the complete Title 24 guide →

Title 24 by City

We serve all of California — see all locations.

Why Choose T24Report for Commercial Title 24?

  • Custom Quote — Priced by Project Scope
  • Free Project Scope Review
  • NRCC Compliance for Nonresidential Buildings
  • CEC-Approved Compliance Software
  • Prescriptive & Performance Paths
  • Standard, Rush & Same-Day Options
  • Two Revisions Included
  • 100% Online — Statewide California

Ready for Your Commercial Title 24 Quote?

Upload your commercial plan set and we'll scope every regulated system and return a custom quote — standard, rush, and same-day options available.

Contact Us