A commercial tenant improvement (TI) adapts existing nonresidential space for a new tenant or use. Under California’s Energy Code (Title 24, Part 6), the compliance scope is driven entirely by what you alter — lighting, HVAC, envelope, or added conditioned area — so two TIs of the same size can need very different documentation.

How TI scope is determined

The Energy Code treats alterations by system. Reworking the indoor lighting pulls in the indoor lighting certificate (NRCC-LTI); changing HVAC equipment or distribution pulls in the mechanical certificate (NRCC-MCH); altering walls, roof, or glazing pulls in the envelope certificate (NRCC-ENV); and changing exterior fixtures pulls in outdoor lighting (NRCC-LTO). A TI that only refinishes surfaces with no regulated systems may fall outside the energy scope — but that should be documented rather than assumed.

Prescriptive vs performance, and field steps

Most TIs comply prescriptively, meeting each altered component’s requirement, but the performance path (whole-building modeling) can help when a design does not meet a prescriptive item. Our report is the design-stage NRCC package for permit. During construction, installation certificates (NRCI) and acceptance testing (NRCA) by a certified technician verify that controls and equipment perform as documented.

Documents and timeline

The fastest commercial TI reviews start with a complete, coordinated plan set, because the energy scope is read directly from the drawings. Architectural plans, a lighting plan with a controls narrative, and mechanical schedules for any HVAC changes are usually enough to identify the required certificates and produce them. Missing or inconsistent sheets are the most common cause of delay in commercial energy review. Once we can see the full scope, standard, rush, and same-day options are available, and we confirm a firm timeline with your quote.

What we need to quote and prepare your report

Send the plan set so we can scope only the systems your TI actually alters:

Example project

Illustrative example — not a specific customer: A 2,800-square-foot suite is re-tenanted with new LED lighting and controls but keeps the existing HVAC and envelope. Because only lighting is altered, the project needs NRCC-LTI plus acceptance testing of the installed lighting controls — no mechanical or envelope certificates are required.

Commercial Title 24 pricing

Commercial projects are quoted individually — priced by building type, conditioned floor area, compliance path, and the systems in scope, not a flat rate. Upload your plans for a firm quote, with standard, rush, and same-day options.

Request a commercial quote →

← Back to Commercial Title 24 · All services · Request a quote

Questions & Answers

Does every commercial TI need a Title 24 report?
Only the systems you alter are regulated. Change lighting, HVAC, or envelope and the corresponding NRCC certificate is generally required; a finishes-only TI with no regulated systems may not. Confirm with your building department.
Can you tell me what my TI needs before I commit?
Yes — send the plans and scope and we identify which NRCC certificates apply, then quote accordingly.
Is lighting-only the most common TI scope?
It is very common. Lighting-only TIs usually need the indoor lighting certificate and acceptance testing of the installed controls.
What is acceptance testing?
A field verification (NRCA) performed during construction by a certified technician to confirm installed lighting controls and HVAC equipment operate correctly — separate from our design-stage report.
Do you handle plan-check energy corrections?
Yes. Send the correction list and relevant sheets and we resolve the flagged NRCC items.
How is a TI priced?
By which systems are in scope and building size — not a flat rate. Upload plans for a firm custom quote.

Related Title 24 Topics

Browse the complete Title 24 guide →

Title 24 by City

We serve all of California — see all locations.

Why Choose T24Report for Commercial Title 24?

  • Custom Quote — Priced by Project Scope
  • Free Project Scope Review
  • NRCC Compliance for Nonresidential Buildings
  • CEC-Approved Compliance Software
  • Prescriptive & Performance Paths
  • Standard, Rush & Same-Day Options
  • Two Revisions Included
  • 100% Online — Statewide California

Ready for Your Commercial Title 24 Quote?

Upload your commercial plan set and we'll scope every regulated system and return a custom quote — standard, rush, and same-day options available.

Contact Us